Description
APW12A power supply needs to be equipped with approved C-type 20A circuit breaker as over-current protective device to be installed external to the equipment.
For S19j Pro-A/S19 Pro-A Air-cooling Miner |
||
OUT1 | DC Voltage | 12V-15V |
Rated Current(220 V input) | 233A | |
Ripple & Noise | <1% | |
Line Regulation | <1% | |
Load Regulation | <1% | |
Setup Time | <2S | |
Short Circuit Protection | >10mS | |
OUT2 | DC Voltage | 12.3V |
Rated Current(220 V input) | 15A | |
Ripple & Noise | <1% | |
Voltage Accuracy | 12.2V—12.4V | |
Line Regulation | <1% | |
Load Regulation | <1% | |
Setup Time | <2S | |
Short Circuit Protection | >10mS | |
Input | Voltage Range | 277V AC ±10% |
Frequency Range | 60Hz | |
Power Factor | >0.99(full load) | |
Leakage Current | <1.5mA(220V 50Hz) | |
Protection | Low-voltage Input | 170V-180V AC |
Output Short Circuit | Yes | |
Overheat Protection | Yes | |
Over-current Output | 291A-350A
(protection value varies under different voltage) |
|
Environment | Operating Temperature | -20-45℃ |
Operating Humidity | 20%-90%RH(non-condensing) | |
Altitude | < 2000m | |
Structure | Dimensions | 254.6mm*251.6mm*63mm |
Net Weight | 3.6KG | |
Cooling System | forced‐air cooling | |
Noise | 45dBA |
Discussions